Summary:...
1. Under normal circumstances, for a long-term continuous work reducer, the new oil should be replaced after 5000 hours of operation or once a year. For the long-term deactivated reducer, the new oil should be replaced before re-operation. The reducer should be added with the same grade The oil must not be mixed with oils of different brands. Oils with the same brand but different viscosity are allowed to be mixed.
2. When changing the oil, wait for the reducer to cool down and there is no danger of burning, but it should still be kept warm, because after the complete cooling, the viscosity of the oil increases and it is difficult to drain the oil. Note: Cut off the power supply of the drive unit to prevent accidental power-on!
3. During work, when the oil temperature rises above 80°C or the oil pool temperature exceeds 100°C and abnormal noise is found, stop using it. Check the cause, remove the fault, and replace the lubricating oil before continuing to run.
4. The user should have reasonable use and maintenance rules and regulations, and carefully record the operation of the reducer and the problems found during the inspection. The above regulations should be strictly implemented.